{"id":3345,"date":"2026-11-27T13:42:36","date_gmt":"2026-11-27T05:42:36","guid":{"rendered":"https:\/\/www.weldmc.com\/news\/portable-water-jet-cutting-what-the-site-must-supply\/3345\/"},"modified":"2026-11-27T13:42:36","modified_gmt":"2026-11-27T05:42:36","slug":"portable-water-jet-cutting-what-the-site-must-supply","status":"publish","type":"post","link":"https:\/\/www.weldmc.com\/es\/noticias\/portable-water-jet-cutting-what-the-site-must-supply\/3345\/","title":{"rendered":"Portable Water Jet Cutting: What the Site Must Supply"},"content":{"rendered":"<p>Portable water jet cutting is usually chosen because the work cannot come to the machine. A tank shell, a ship section, a pipe spool, or a bundle of structural beams has to be cut where it stands, so the cutter travels to it. That decision moves the constraint from the machine to the site. The intensifier pump, the hydraulic cooling circuit, the abrasive feed, and the control system all depend on two services that workshops rarely plan in detail: an electrical supply that carries starting and running loads without a significant dip, and a water supply that holds both flow and pressure through a full cut. Both are specified from measurements, not from a utility bill or a tap that looks adequate when nothing is running.<\/p>\n<h2>Why Power and Water Decide Whether a Portable Water Jet Runs<\/h2>\n<p>The cutting energy in a water jet comes from pressure, not from the size of the package. A hydraulic pump drives a small water piston inside the intensifier, and the ratio between the two areas multiplies oil pressure into cutting pressure at the outlet. That pressure becomes velocity as the water passes through an orifice a fraction of a millimetre across, and abrasive is drawn into the resulting stream. Three consequences follow for the site. Water must arrive at the pump inlet faster than the intensifier consumes it, because the pump cannot draw against a collapsing supply. The water must be clean enough that the orifice and the check valves keep their geometry. The electrical supply must carry the hydraulic pump&#8217;s starting current, not only its running current, because a motor that stalls or trips at start never reaches cutting pressure.<\/p>\n<p>Pressure stability shows up directly in cut quality. If inlet flow drops for a moment, the intensifier cannot hold pressure, the jet loses velocity, and the kerf widens or becomes tapered; on thicker plate the stream lags and the lower edge is left rough. Operators often read that as a worn nozzle or a wrong abrasive setting and replace consumables that were not the problem. Supply history is the first thing to check, which is why measured readings matter more here than any single machine specification.<\/p>\n<p>Call the combination the supply envelope: the electrical capacity, the water flow and quality, the drain capacity, and the access the site commits to before the unit arrives. A portable machine is portable in the sense that the cutting head and pump package can be moved; the envelope stays behind, and every site has a different one. That is why the same model can cut cleanly in one workshop and fault repeatedly twenty kilometres away. The envelope also explains why field work in shipyards, tank farms, and structural steel yards is where portable units earn their place. The parts are large, the access is awkward, and the alternative is moving a workpiece that weighs more than the machine.<\/p>\n<blockquote>\n<p>In shipyard work, cutting and welding equipment compete for the same access and the same floor space, so both are planned around the workpiece rather than the other way round. &lt;<a href=\"https:\/\/www.weldmc.com\/es\/noticias\/revolucion-en-la-soldadura-naval-como-los-posicionadores-de-soldadura-mejoran-la-calidad-y-la-eficacia\/1711\/\">Revolution in Ship Welding: How Welding Positioners Improve Quality and Efficiency<\/a>&gt; covers how positioning equipment improves weld quality and efficiency in ship construction.<\/p>\n<\/blockquote>\n<h2>Electrical Supply Requirements for Portable Water Jet Cutting<\/h2>\n<p>The electrical load on a portable water jet is not one motor. It is the hydraulic pump that drives the intensifier, a feed or booster pump if the site needs one, a cooling circuit, the control cabinet, the abrasive feeder, and, where the head is mounted on a carriage, the traverse drives. Each has its own draw, and the supply has to be sized from their sum rather than from the pump alone. The machine&#8217;s electrical equipment is also covered by the general machinery standard IEC 60204-1, which addresses protective bonding, isolators, and control functions rather than your building&#8217;s capacity [1]. A declaration of conformity to that standard says the machine was built to it; it says nothing about whether the site can feed it.<\/p>\n<h3>Voltage, Phase, and Full-Load Current<\/h3>\n<p>Start with the intensifier motor nameplate and the ratings of every other motor, heater, and transformer on the package. Record voltage, phase, frequency, full-load current, and service factor for each, then add the control load. Compare the total with the circuit that will actually be used, including the protective device and the cable. A circuit that has fed welders or a small compressor may still be inadequate for two reasons: the intensifier runs continuously through a long cut rather than intermittently, and its starting current is drawn against a load that is already warm. If the unit is built for one voltage and the site runs another, a transformer is not a formality; it changes the fault current and may change the protection settings.<\/p>\n<h3>Mains Power Versus a Generator<\/h3>\n<p>A generator can make a portable water jet independent of the building, but only when it is selected for motor starting rather than for the sum of running load. Starting current can reach several times the running current for a fraction of a second, and the generator&#8217;s voltage response during that fraction decides whether the control system stays up. Frequency stability matters for the same reason when drives are inverter-fed: a generator that holds voltage while frequency wanders can push a drive into a fault. Generator ratings are also quoted at stated conditions, and available output falls as altitude rises and ambient temperature climbs, so a datasheet figure taken at sea level should not be assumed at a hot, high site. Ask for the derated value or leave margin for it.<\/p>\n<h3>Cable Length, Earthing, and Protection<\/h3>\n<p>Long cable runs between the distribution board or generator and the machine do two things: they drop voltage under load, and they raise the impedance the protection sees. Both matter more where the machine stands outdoors, the cable crosses wet ground, and the workpiece is a large steel structure. Protective bonding of the frame, the workpiece, and adjacent steelwork belongs in the installation plan, not in a later correction. The high-pressure water jet machine as a whole falls under EN 1829-1, which sets safety requirements for machines of this type [2]. On site, confirm the earth fault protection trips with the machine connected, and confirm the earthing arrangement has not changed because the unit is now fed from a generator.<\/p>\n<table>\n<thead>\n<tr>\n<th>Record<\/th>\n<th>How it was produced<\/th>\n<th>What it can support<\/th>\n<th>Do not infer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Motor nameplate<\/td>\n<td>Read at the machine, includes service factor<\/td>\n<td>Circuit, cable, and isolator planning<\/td>\n<td>The running current you will measure at this site<\/td>\n<\/tr>\n<tr>\n<td>Utility demand history<\/td>\n<td>Billing-period averages from the utility<\/td>\n<td>Whether an existing service has spare capacity<\/td>\n<td>That the service can absorb the starting current<\/td>\n<\/tr>\n<tr>\n<td>Generator datasheet rating<\/td>\n<td>Manufacturer rating at stated conditions<\/td>\n<td>Like-for-like comparison between generators<\/td>\n<td>That the same output is available at site altitude and temperature<\/td>\n<\/tr>\n<tr>\n<td>Earth fault loop measurement<\/td>\n<td>Taken by the utility or an electrical contractor<\/td>\n<td>Whether installed protection will operate as intended<\/td>\n<td>That the same settings suit a generator-fed supply<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These records describe the supply. None of them describes how the machine behaves under load, which is why the commissioning checks later in this article measure rather than assume.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.weldmc.com\/wp-content\/uploads\/2025\/11\/Industrial-Positioner-Unit_20251130_163518.webp\" alt=\"Posicionador industrial\" style=\"max-width: 600px; height: auto; display: block; margin: 20px auto;\" \/><\/p>\n<h2>Water Supply Requirements and Water Quality<\/h2>\n<p>A portable water jet can have two separate water demands and one that is easily forgotten. The first is feed water: the volume the intensifier consumes and discharges through the cutting head. The second is cooling water for the hydraulic circuit, which may be a closed loop with a heat exchanger or a once-through connection depending on the design. The third is the drain, because whatever passes through the head comes back out carrying abrasive and fines, and it has to go somewhere the site controls. A supply plan covering only the first is incomplete.<\/p>\n<h3>Flow and Pressure at the Inlet<\/h3>\n<p>Static pressure at a tap proves very little. A gauge on a closed line can show a healthy reading while the same line collapses the moment the intensifier starts drawing. What matters is the pressure at the pump inlet while the machine is cutting, and that value has to stay above the pump&#8217;s inlet requirement for the whole cut. A dedicated line sized for the demand and taken from a point close to the machine is the straightforward answer. Where the site cannot provide that, the usual arrangement is a break tank with a booster pump: the tank absorbs variation in the building supply, the booster delivers a stable inlet pressure, and the intensifier sees a consistent condition. The trade-off is footprint and one more item to maintain.<\/p>\n<p>Air entrained in the feed is worse than low pressure, because it collapses in the intensifier and makes pressure oscillate. A suction line with a loose joint, or a tank allowed to run low, produces exactly the symptoms of a failing pump.<\/p>\n<h3>Filtration, Hardness, and Orifice Protection<\/h3>\n<p>Filtration protects two different things. A coarse sediment filter at the connection stops grit that would damage the inlet check valves; a finer filter downstream protects the orifice and the cutting head. Fit a differential gauge across each filter, because a loaded filter looks exactly like a supply problem from the operator&#8217;s position. Hardness is a separate issue that filtration does not solve. Calcium and magnesium stay dissolved through a sediment filter and come out of solution where pressure and temperature change, which is inside the intensifier and around the orifice. Scale there reduces flow, disturbs the jet, and eventually forces a rebuild. Ion exchange softening or reverse osmosis removes hardness; softening carries a regeneration cost and a salt discharge, while reverse osmosis produces a reject stream the drain plan has to accept. Either is usually cheaper than repeated seal and valve work, but neither is free.<\/p>\n<h3>Drain, Catch Tank, and Slurry Handling<\/h3>\n<p>The drain belongs in the supply envelope because the machine cannot run without it. Water leaving the cutting head carries abrasive and fine material, so it cannot enter a general drain without settling. A catch tank with a settling section and a removable screen is the common arrangement for field work. Size it for a full shift rather than for a test cut, and decide how the settled solids leave the site. On outdoor work, add freezing to the list of conditions: a tank, line, or pump left full in sub-zero weather fails at the least convenient moment.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.weldmc.com\/wp-content\/uploads\/2025\/11\/Automated-Welding-Positioner_20251130_163400.webp\" alt=\"Posicionador de soldadura automatizado\" style=\"max-width: 600px; height: auto; display: block; margin: 20px auto;\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Why it matters at the head<\/th>\n<th>How to verify on site<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Inlet flow during a cut<\/td>\n<td>The intensifier cannot draw against a collapsing supply<\/td>\n<td>Flow meter at the inlet during a production cut<\/td>\n<\/tr>\n<tr>\n<td>Inlet pressure during a cut<\/td>\n<td>Low inlet pressure causes cavitation and pressure oscillation<\/td>\n<td>Gauge at the pump inlet, read while cutting<\/td>\n<\/tr>\n<tr>\n<td>Suspended solids<\/td>\n<td>Plug filters and erode the orifice<\/td>\n<td>Filter differential plus a water sample<\/td>\n<\/tr>\n<tr>\n<td>Hardness<\/td>\n<td>Scale forms in check valves and at the orifice<\/td>\n<td>Laboratory analysis of a sample taken at the connection<\/td>\n<\/tr>\n<tr>\n<td>Water temperature<\/td>\n<td>Hot feed shortens seal life and cuts cooling margin<\/td>\n<td>Thermometer at the inlet during a long cut<\/td>\n<\/tr>\n<tr>\n<td>Drain capacity<\/td>\n<td>Slurry has to settle before disposal<\/td>\n<td>Tank level change measured across a shift<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Site Layout and Ancillary Services for Field Operation<\/h2>\n<p>A field layout has more parts than the machine. The pump package, control cabinet, abrasive hopper, catch tank, water line, cable route, and operator position all need a place, and the cutting head needs a clear exclusion zone in front of it. Plan from the cut backwards: where the head must reach, where the water and slurry land, where the tank sits, and only then where the pump and controls go. Planning outwards from the machine usually ends with a hose that is too short or a cable route across a walkway.<\/p>\n<p>Access for service is a supply requirement in practice. Seals, check valves, and filters are consumables, and a pump boxed into a corner gets run until it fails rather than serviced on schedule. Leave the panels that open accessible, keep filter housings reachable without dismantling the water line, and keep cable and hose routes off the floor where traffic crosses.<\/p>\n<blockquote>\n<p>A layout that fits the cut but blocks service access usually costs more than the space it saved, and the same logic applies to fixed workshop equipment. &lt;<a href=\"https:\/\/www.weldmc.com\/es\/noticias\/workshop-space-too-small-how-column-booms-save-50-floor-space-while-boosting-safety-efficiency\/1740\/\">\u00bfEspacio de taller demasiado peque\u00f1o? C\u00f3mo las columnas ahorran espacio 50% a la vez que aumentan la seguridad y la eficiencia<\/a>&gt; covers how column and boom configurations reduce floor space use while keeping service access and operator safety workable.<\/p>\n<\/blockquote>\n<p><img decoding=\"async\" src=\"https:\/\/www.weldmc.com\/wp-content\/uploads\/2025\/11\/Structural-Welding-Positioner_20251130_163626.webp\" alt=\"Posicionador de soldadura estructural\" style=\"max-width: 600px; height: auto; display: block; margin: 20px auto;\" \/><\/p>\n<h3>Abrasive Storage and Handling<\/h3>\n<p>Abrasive is the consumable that fails quietly. Garnet that has taken up moisture bridges in the hopper and feeds unevenly, which shows as a jet that cuts well, then stops cutting, then cuts again. Store abrasive dry, keep the hopper lid closed, and check the feed line for damp pockets after humid weather. Dust from handling is a respiratory issue, so fill outdoors or with extraction running.<\/p>\n<h3>Workpiece Support, Noise, and Water Mist<\/h3>\n<p>Supporting the workpiece is part of the layout, not an afterthought. Cutting plate on trestles with clear space beneath gives the jet somewhere to go and stops it reflecting back into the kerf; an off-cut that shifts mid-cut will pinch the head or break the stream. Portable units are also not quiet, and the noise comes from the jet rather than from the motor. Measure it at the operator position and screen the area where exposure is long. Expect visible mist as well. Ventilation and a sensible operator position do more for a site than a face covering alone.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.weldmc.com\/wp-content\/uploads\/2025\/11\/20T-welding-positioner3_20251130_163340.webp\" alt=\"Posicionador de soldadura de 20 toneladas 3\" style=\"max-width: 600px; height: auto; display: block; margin: 20px auto;\" \/><\/p>\n<h2>Pre-Commissioning Checks Before the First Cut<\/h2>\n<p>These checks are made with the machine installed and the services connected, before production work starts. Each produces a record, and those records are what an operator refers to when a fault appears months later.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.weldmc.com\/wp-content\/uploads\/2025\/11\/Wind-Tower-Positioner_20251130_163700.webp\" alt=\"Posicionador de torre e\u00f3lica\" style=\"max-width: 600px; height: auto; display: block; margin: 20px auto;\" \/><\/p>\n<ol>\n<li><strong>Verify the circuit against the nameplate.<\/strong> Compare the protective device rating, cable size, and isolator with the sum of the machine&#8217;s loads, and confirm the bond between the frame and the site earth is in place.<\/li>\n<li><strong>Read voltage at the machine terminals under load.<\/strong> Open-circuit voltage proves the line is live, not that it can carry the pump. Record terminal voltage while the intensifier runs at cutting pressure and compare it with the reading at the distribution board.<\/li>\n<li><strong>Clamp the current on each phase.<\/strong> A high or badly unbalanced reading points to a supply or connection problem rather than a machine fault.<\/li>\n<li><strong>Measure inlet flow and pressure during a cut, not before and not after.<\/strong> A gauge read while the machine idles is the most common source of false confidence in a water supply.<\/li>\n<li><strong>Record filter differential when clean and again after a shift.<\/strong> That gives the operator a baseline for deciding when a filter is loaded.<\/li>\n<li><strong>Run a test cut on scrap of the production thickness.<\/strong> Record pressure stability, kerf width at top and bottom, and the finish of the cut face. Repeat the test whenever the water source changes.<\/li>\n<li><strong>Test the earth fault protection with the machine connected.<\/strong> If the unit runs from a generator, log voltage and frequency through a start and through a loaded cut.<\/li>\n<li><strong>Run the catch tank for a full shift.<\/strong> Confirm the level rise and the settling behaviour match the disposal plan before throughput increases.<\/li>\n<\/ol>\n<h2>Common Supply Problems and How They Show Up<\/h2>\n<p>Most supply faults reach the operator as a cutting problem, so the first response is often to change consumables. The table below maps the visible symptom to the supply condition that produces it and the check that separates them.<\/p>\n<table>\n<thead>\n<tr>\n<th>Symptom<\/th>\n<th>Supply condition that produces it<\/th>\n<th>First check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Pressure falls partway through a cut and recovers when the jet stops<\/td>\n<td>Inlet flow below demand, or air drawn into the feed<\/td>\n<td>Inlet pressure and flow read during the cut<\/td>\n<\/tr>\n<tr>\n<td>Pump knocks or runs rough, seals fail early<\/td>\n<td>Inlet pressure below the pump requirement, or cavitation from trapped air<\/td>\n<td>Inlet pressure under load and inspection of suction joints<\/td>\n<\/tr>\n<tr>\n<td>Unit runs on mains but trips the generator at start<\/td>\n<td>Starting current beyond generator capability, or a voltage dip that drops the control system<\/td>\n<td>Voltage and frequency log through a start<\/td>\n<\/tr>\n<tr>\n<td>Jet loses focus and the kerf widens over a shift<\/td>\n<td>Solids reaching the orifice, or scale in the check valves<\/td>\n<td>Filter differential plus a water sample<\/td>\n<\/tr>\n<tr>\n<td>Hydraulic oil temperature alarms on long cuts<\/td>\n<td>Cooling water flow or temperature outside the design condition, or restricted airflow at the cooler<\/td>\n<td>Coolant flow and inlet water temperature during a long cut<\/td>\n<\/tr>\n<tr>\n<td>Drives fault out and the head stops tracking<\/td>\n<td>Frequency or voltage instability from the generator supply<\/td>\n<td>Power quality log during the fault<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Two of these deserve a warning. A jet that widens gradually is often treated as normal wear, so a real supply problem can run for weeks before anyone measures the water. A generator trip at start is often blamed on the control system when the record would show voltage collapsing before the drive faulted. The measurement takes minutes and settles the question.<\/p>\n<h2>Send the Site Data Before the Machine Is Specified<\/h2>\n<p>Portable water jet cutting is specified from the site, not from a catalogue. The usable specification comes from the supply envelope: the voltage, phase, and current available continuously, the generator rating and the conditions it will run in, the inlet flow and pressure measured under load, a water analysis, the drain or catch tank arrangement, the material and thickness range, the largest part envelope, and the cut window the schedule allows. With those figures the machine, the filtration, and the installation can be matched to the site instead of being adjusted after delivery.<\/p>\n<p>Nameplate data alone cannot confirm that a supply will hold pressure through a full production cut, and a quotation built only on it should be treated as a starting point rather than a specification. Send the site data to jay@weldc.com or call +86-510-83555592 at WUXI ABK MACHINERY CO., LTD, and the supply and the machine can be checked against each other before the order is placed.<\/p>\n<h2>PREGUNTAS FRECUENTES<\/h2>\n<h3>Can a portable water jet cutter run from a standard shop outlet?<\/h3>\n<p>Only where that outlet is a dedicated circuit rated for the machine&#8217;s full load and starting current, which a general-purpose outlet rarely is. Check the nameplate sum, the protective device, and the cable, then measure voltage at the machine while the pump runs. A circuit that has fed welders or a compressor may still be too small, because the intensifier runs continuously through a long cut. If the outlet cannot carry the load, a dedicated supply or a correctly sized generator is the answer, not a longer extension lead.<\/p>\n<h3>How much water does portable water jet cutting use?<\/h3>\n<p>The volume is set by the pump and the orifice, so it should be taken from the machine&#8217;s own data rather than estimated. What matters operationally is that the supply delivers that flow continuously at the required inlet pressure for as long as a cut lasts, and that the drain accepts what comes out. Most of the water returns as slurry with the abrasive, which is why a settling tank belongs in the plan. Where the building supply is limited, a break tank and booster buffers the machine from the line.<\/p>\n<h3>Will a generator replace a mains connection on a field site?<\/h3>\n<p>It can, provided the generator is selected for motor starting rather than for the sum of running load, and derated for the altitude and ambient temperature at the site. Two further conditions decide whether it works. The earthing arrangement changes when the machine is fed from a generator, and inverter-fed drives are sensitive to frequency instability even when voltage looks acceptable. Log voltage and frequency through a start and a loaded cut, and keep the record for comparison when a fault appears later.<\/p>\n<h3>Does water hardness matter if the water is filtered?<\/h3>\n<p>Yes. Filtration removes suspended solids, while hardness is dissolved and passes straight through a sediment filter. It comes out of solution where pressure and temperature change, inside the intensifier and around the orifice. Scale there disturbs the jet and forces valve and seal work. Softening or reverse osmosis addresses it, each with its own running cost and waste stream. A water analysis taken at the point of connection is the cheapest way to decide whether either treatment is needed.<\/p>\n<h3>What causes pressure loss in the middle of a cut?<\/h3>\n<p>The usual causes are inlet starvation, air drawn into the feed, a loading filter, or wear at the orifice and check valves. Separate them by measuring inlet pressure and flow while the machine is cutting. If the inlet holds, the problem sits downstream of the pump; if it falls, the supply is the cause. Pressure that recovers when the jet stops is a strong signal of a supply that cannot keep up rather than a pump failure.<\/p>\n<h2>References<\/h2>\n<p>[1] IEC 60204-1:2016, &#8220;Safety of machinery \u2014 Electrical equipment of machines \u2014 Part 1: General requirements,&#8221; International Electrotechnical Commission, 2016.<\/p>\n<p>[2] EN 1829-1:2010, &#8220;High-pressure water jet machines \u2014 Safety requirements \u2014 Part 1: Machines,&#8221; European Committee for Standardization, 2010.<\/p>\n<p>Si te interesa, echa un vistazo a estos art\u00edculos relacionados:<\/p>\n<p><a href=\"https:\/\/www.weldmc.com\/es\/noticias\/el-pilar-central-de-la-fabricacion-pesada-el-extraordinario-rendimiento-de-los-soportes-de-rodillos-en-procesos-clave\/2189\/\">El pilar central de la fabricaci\u00f3n pesada: El extraordinario rendimiento de los soportes de rodillos en procesos clave<\/a><br \/>\n<a href=\"https:\/\/www.weldmc.com\/es\/noticias\/manipuladores-de-soldadura-para-la-fabricacion-de-torres-eolicas-que-revolucionan-la-eficacia-de-la-produccion\/1684\/\">Manipuladores de soldadura para la fabricaci\u00f3n de torres e\u00f3licas: Revolucionando la eficiencia de la producci\u00f3n<\/a><br \/>\n<a href=\"https:\/\/www.weldmc.com\/es\/noticias\/desalineacion-excesiva-en-la-soldadura-de-tuberias-wuxi-abk-welding-turntable-precision-positioning-solution\/1692\/\">Desalineaci\u00f3n excesiva en la soldadura de tuber\u00edas: soluci\u00f3n de posicionamiento de precisi\u00f3n con mesa giratoria de soldadura de Wuxi ABK<\/a><br \/>\n<a href=\"https:\/\/www.weldmc.com\/es\/noticias\/wuxi-abk-profesional-de-soldadura-equipos-rotativos-de-soldadura-de-precision-solucion-para-la-fabricacion-de-recipientes-a-presion\/1665\/\">Equipos rotativos de soldadura profesional ABK de Wuxi: soluci\u00f3n de soldadura de precisi\u00f3n para la fabricaci\u00f3n de recipientes a presi\u00f3n<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Portable water jet cutting is usually chosen because the work cannot come to the machine. A tank shell, a ship section, a pipe spool, or a bundle of structural beams has to be cut where it stands, so the cutter travels to it. That decision moves the constraint from the machine to the site. The [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2387,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3345","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/posts\/3345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/comments?post=3345"}],"version-history":[{"count":0,"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/posts\/3345\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/media\/2387"}],"wp:attachment":[{"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/media?parent=3345"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/categories?post=3345"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.weldmc.com\/es\/wp-json\/wp\/v2\/tags?post=3345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}